A 5 year study conducted at Texas A&M University and jointly funded by AirField Systems and the United States Golf Association showed that the AirDrain System provides up to 3 days of plant-available water beyond the USGA recommended gravel and sand profile.

ImageImage

Airfield Systems offers an alternative to the standard USGA putting green design. Their design utilizes a highly porous, 1-inch deep plastic grid (AirDrain, Figure 1) in place of a 4-inch deep gravel layer. As with gravel, AirDrain allows rapid lateral movement of excess water to drains and thus provides for uniform horizontal moisture content within the root zone. While voids in AirDrain are very effective in transmitting water, they are much too large for the sand in the root zone to bridge for self-support so a geotextile is used atop the grid to prevent infilling of the void space. Use of geotextiles in putting green construction has been controversial due to the perceived potential for clogging of the fabric by migrating fine particles and eventual loss of permeability.

We became interested in the hydraulic performance of the Airfield Systems design after Texas A&M University constructed a soccer field with the Airfield System design in 2002. Anecdotal evidence from field managers suggested that the new field required less frequent watering than the University's football field that had been constructed following the USGA design. While the two fields were constructed with different root zone mixtures and the physical environments surrounding the fields are quite different, we suspected that there may have been a difference in the amount of water stored in root zones on fields constructed with the two designs (i.e., a difference in the vertical distributions of water content in the root zones). We knew from the physics of water in sand that the amounT of water stored in a root zone decreases with increasing tension at the bottom of the root zone, and we expected because of the geometrical and physical differences in the designs that there would be differences in water tension at the bottom of the root zones.

AirDrain, natural grass drainage, usga, golf construction, putting green construction

The highly porous, 1-inch deep AirDrain (right) offers an alternative to the 4-inch deep gravel layer in the standard USGA putting green design.

While the root zone may be saturated above the drainage layer, the water is under tension so the term "perched water table" often used to describe the state of water in the root zone immediately above the drainage layer is a bit of a misnomer. A better term might be "perched capillary fringe." Capillary fringe is the saturated zone above a water table where water is under tension. The further upward from the bottom of the root zone the greater the water tension. As distance increases upward and water tension increases, the root zone eventually begins to desaturate as the largest pores drain. As distance increases beyond this height water content continues to decrease. As a consequence, the tension that develops at the bottom sets the starting tension and determines the thickness of the saturated zone and the amount of water stored in the root zone profile. The depth and hydraulic properties of the drainage layer determine the magnitude of tension that develops at the bottom of the root zone. AirDrain is 1-inch deep so the maximum tension that can develop at the bottom of the root zone during drainage in the Airfield Systems design would be 1 inch of water. Gravel is typically 4 inches deep so the tension that could develop would be up to 4 inches of water, depending on the hydraulic properties of the gravel and the depth to which sand ingresses pores of the gravel. Water is slow to drain from small pores into large pores, but if both systems were sealed from evaporation the tensions would eventually reach 1 and 4 inches at the bottom of the root zone in the Airfield Systems and USGA design greens, respectively. An occasional finger of sand penetrating the gravel in the USGA design green can lead to an appreciably quicker increase in tension at the root zone gravel interface.

AirDrain, natural grass drainage, usga, golf construction, putting green construction

CROSS SECTION OF A PUTTING GREEN USING THE AIRDRAIN SYSTEM INSTEAD OF A 4-INCH GRAVEL LAYER IN A USGA GREEN.

To test for differences in tension developed at the bottom of the root zones of the two designs, we constructed laboratory-based test cells from 4-inch diameter PVC pipe containing profiles of the Airfield Systems and USGA greens. Using tensiometers, we were able to demonstrate that the tension that developed at the bottom of the root zone in the Airfield Systems design was appreciably less than that in the USGA design. At that point we thought it worthwhile to investigate this finding on a slightly larger scale and a more realistic setting. To this end, we constructed test greens in 14-inch diameter PVC pipe. Three sands and three gravels were chosen such that they covered the ranges from coarser to finer sides of the USGA recommendations for particle size distribution. To create root zone mixtures, the coarser two sands had peat moss added to increase water retention. The finer sand was not amended. These three root zone mixtures were used in combination with the three gravels to construct test greens of the USGA design. The gravel layer in all of the test greens was 4 inches deep. An intermediate choke layer of coarse sand was not used. The same three root zone mixtures were used in combination with four geotextiles atop AirDrain to construct test greens of the Airfield Systems design. We used the Lutradur polyester geotextile prescribed by Airfield Systems at the time and chose three additional geotextiles that had the same apparent opening size (0.2 mm), but differed in material and/or manner of construction. Manometer­ tensiometers were used to measure pressure or tension that developed at the root zone-drainage layer interface of both designs. After the test green columns were packed with 12 inches of the root zone mixtures they were sprigged with MiniVerde bermudagrass supplied by King Ranch Turfgrass­ Wharton Farms (Wharton, TX). Following a period to grow-in the grass, a series of experiments were conducted that measured the amount of water stored in the root zone profiles and the water tension that developed at the bottom of the root zones of the different treatments after irrigation and drainage.

Vertically oriented time domain reflectometry TDR probes were used to measure the amount of water stored in the root zone profiles.

water tension
water content

Graphic representation of the dependence of water-holding capacity on tension at the bottom of the profile for a typical root zone mixture meeting USGA recommendation for total, air-filled, and ca­ pillary porosities. The curved lines to the right rep­ resent the relationship between water tension and water content for the root zone mixture.

Periodically during the course of the study, the test greens were watered until drainage was observed and then the amount of water stored in the profiles and the water tension at the bottom of the root zones were recorded for 48 hours. As with our preliminary lab study, we found that the water at the bottom of the root zones of test greens constructed with the Airfield design was under less tension than the water in test greens constructed with the USGA design, by about 2.2 inches of water tension. This lower tension was associated with an increase in water storage of about 0.5 inch in the Airfield System design greens above that in the USGA design greens. This increase in water retention could lead to less frequent necessity to irrigate.

Because of reduced tension at the bottom of the root zone, these results also implied that the tension at which root zone mixtures should be tested for capillary porosity when intended to be used in an Airfield System design green should be reduced to achieve similar moisture retention to greens built according to the USGA recommendations. In doing so, slightly more coarse sand would meet specifications for capillary water retention in the Airfield design. Conversely, sands that push the very fine side of the current recommendations might not meet specifications for air-filled porosity.

The question of whether or not geotextiles used in a green will clog with fines migrating out of the root zone was also studied. To address this issue, we conducted a year-long laboratory experiment to investigate a range of geotextiles that were suited to supporting sand in the Airfield System design and determine whether or not they limit drainage out of the root zone. In this experiment, 6-inch diameter PVC columns were used to contain combinations of 12 inches of three sand mixes with 10 geotextiles held atop AirDrain. Manometer-tensiometers again were used to measure pressure or tension at the sand-geotextile interfaces.

Mix 1 had a particle size distribution that ran down the center of the USGA specs. Mix 2 was made by blending Mix 1 with a sandy clay loam (9:1 by mass) and Mix 3 was made by blending Mix 1 with a sand having excess fines (1:1 by mass). Mix 1 and Mix 2 met USGA recommendations. Mix 3 contained twice the recommended amount of very fine sand. The apparent opening sizes of the geotextiles used ranged from O.15 to 0.43 mm. After the sands were added to the columns they were regularly irrigated. Periodically, the rate that 1-inch of irrigation water drained from a column was measured and the pressure/tension at the sand­ geotextile interface was recorded.

AirDrain, natural grass drainage, usga, golf construction, putting green construction

Test greens constructed in 14-inch PVC pipe with either gravel or geotextile atop AirDrain as the drainage layers. Both types of test greens contained a pair of porous cups connected to plastic tubing that formed manometer-tensiometers to allow measurement of water pressure or tension at the root zone­ drainage layer interface.

For the first six months, any particles that washed out of the sand through the geotextiles were accumulated and analyzed for total dry weight and particle size distribution. At the end of the study, the saturated hydraulic conductivity of the sand-geotextile combinations were measured. Statistical analyses showed that drainage rate, saturated hydraulic conductivity, and mass of eluviated particles were not dependent on the properties of the geotextiles, but rather on the properties of the sands. Most all of the particles that washed out of the columns were of clay and silt sizes. This could be construed as evidence that the geotextiles were sieving out larger particles, but we found that the size of particles in the drainage water was not related to the apparent opening size of the geotextiles, which it should have been if the geotextiles were acting as sieves (i.e., the geotextiles with the larger AOS would have let larger particles pass, and vice versa, but this did not happen). The geotextiles obviously prevented the passage of particles as their purpose is to prevent migration of the root zone sand into the drainage layer, but it appeared in our study that the sands were responsible for determining the particle sizes leaving the columns.

Drainage rates from the columns containing the sand without added fines increased over the year, presumably because pore channels in the sand were widened when silt and clay washed out of the profile.

Drainage rates of the columns containing the two sands with additional fines decreased over the year, but the decrease was not statistically related to the properties of the geotextiles. To test if the sands themselves were clogging, saturated hydraulic conductivities were measured as layers of sand were removed from columns. Since saturated hydraulic conductivity would not depend on the depth of sand in a hydraulically uniform column, any observed changes would be due to difference in the conductivity of the layers removed compared to those remaining. We found that when surface layers were removed the saturated hydraulic conductivity increased, indicating that the surface layers had lower conductivities. This was not too surprising as the majority of inter-particle pores of sand meeting USGA recommendations are smaller than the apparent opening sizes of the geotextiles we tested. In support of our conclusion that the sands were clogging and not the geotextiles, we did not notice a build-up of positive pressure atop any of the geotextiles during drainage, as would have occurred if the geotextile had been restricting drainage out of the column.

AirDrain, natural grass drainage, usga, golf construction, putting green construction

Columns used to measure potential clogging of geotextiles by fines migrating out of the root zone.

In conclusion, the results of our studies gave no reason to prevent more widespread use of Airfield Systems' design as an alternative to the USGA method for putting green construction. Airfield Systems design produces additional water holding capacity above the USGA design, which leads to more plant available water, given the same root zone mixture, and, possibly, less frequent requirement for irrigation. Our data also support the general use of properly sized geotextiles to support sand based root zones in putting greens.

Geotextiles with apparent opening size of 0.2 mm worked well in our test greens and a woven geotextile with an apparent opening size twice as large (0.43 mm) retained the root zone sand just as well.

Summary Points:

  • Water at the bottom of the test green rootzones constructed with the Airfield design was under less tension than the water in test greens constructed with the USGA design (about 2.2 inches of water tension).
  • This lower tension was associated with an increase in water storage of about 0.5 inch in the Airfield System design greens above that in the USGA design greens.
  • Geotextiles with apparent opening size of 0.2 mm worked well in test greens and a woven geotextile with an apparent opening size twice as large (0.43 mm) retained the root zone sand just as well.
  • The geotextiles that were tested prevented the migration and passage of the sand rootzone mixture into the drainage layer, but it appeared that the tested sands were responsible for determining the particle sizes leaving the columns.
  • The results gave no reason to prevent more widespread use of Airfield Systems' design as an alternative to the USGA method for putting green construction.
water stored in profile
putting green grass testing usga
rooting medium particle diameter

Range in the mean amount of water stored in 12-inch root zone profiles in Airfield Systems (geotextiles atop AirDrain) and USGA (gravels) design test greens 12 hours after irrigation. Means were of the three root zone mixture treatments and variations shown were from drainage-type treatments (i.e., type of geotextile or gravel). Stored water in the profile was measured by TDR and water tension was measured with manometer­ tensiometers.

Test green with vertically installed, 1-ft long TDR probe used to measure average water content within the root zone profile.

Size distribution of particles washed out of the three sand mixes through the geotextiles. The solid line for each sand mixture represent the mean fraction of particles finer than a given diameter over 30 columns containing the mixture (1 0 geotextiles with 3 replicates) and the dashed lines represent one standard deviation each side of the mean.

Image

Comparison of Putting Greens Constructed with AirField Systems AirDrain Agronomic Drainage and USGA Design

A five year study conducted at Texas A&M University and jointly funded by AirField Systems and the United States Golf Association showed that the AirDrain System provides up to 3 days of plant available water beyond the USGA recommended gravel and sand profile.

ImageImage
read the study

Thousands of installations enjoyed the cost, strength and performance of the AirDrain drainage system.

AirDrain for bunkers

Before you build or renovate a bunker, READ BELOW! Don’t throw your hard earned money away. Choose the easiest and best draining bunker system install there is by far!

Click here to see the ASTM D4716 Flow Rate per Unit Width and Hydraulic Transmissivity Testing for actual drainage capacity, at a 1/2% slope. The AirDrain will actually drain 171 inches per hour. No other product comes close!

Cost value performance and ease of install it’s not even close!

AirDrain Bunkers and Sand Traps are:

  • Simple, Fast, and Easy to Install using existing employees to install at your own pace.
  • NO NEED TO REWORK YOUR CLOGGED HERRINGBONE DRAINAGE SYSTEM. Install over the top!
  • AirDrain replaces the traditional herringbone drainage system!
  • With AirDrain only the exit drain(s) are necessary.
  • The entire bunker floor acts as a drain using gravity to pull the water through the profile. THE FINES SHOULD NEVER CLOG THE SYSTEM! REMEMBER THE ENTIRE FLOOR IS A DRAIN USING GRAVITY!
  • Superior Bunker Drainage with our 1” high 92% air void, allowing water to move without obstruction to the exit drain(s).
  • Long lasting drainage solution. The AirDrain grid itself should retain its performance for 50+ years under a sand profile.
  • Minimal site disturbance with far less excavation and disposal for new bunker construction.


bunker drainage, sand trap drainage, golf drainage, airdrain, billy bunker, capcon

No other product can or does out drain or outlast the AirDrain Bunker System. Pick the worst bunker on your course install our bunker. And then call back in 3 months and order enough for the rest of your bunkers!

AirDrain Proper Sequencing and Orientation


bunker drainage, sand trap drainage, golf drainage, airdrain, sand trap, billy bunker, capcon
bunker drainage, sand trap drainage, golf drainage, airdrain, sand trap, billy bunker, capcon
bunker drainage, sand trap drainage, golf drainage, airdrain, sand trap, billy bunker, capcon

THE AIRFIELD ADVANTAGE


Up to 3 more days of plant-available water stored in the root zone (depending on climate)

Significant reduction of daily irrigation needs up to 40%, as told to us by our customers

Healthier turf / Stronger root system (as told to us by our customers)

100% Vertical Drainage under the entire playing surface

AirDrain is a 100% recycled copolymer with the impact modifier “metallocene” qualifying it as a “No Break” plastic

Helps eliminate standing water / Simplifies maintenance (as told to us by our customers)

Minimal site disturbance / Far less excavation and disposal

Several Installation days are saved over a gravel installation

Reduction in the storage foot print and transportation costs

An AirDrain System sand profile creates its own perched water table

CALL US TODAY TO DISCUSS YOUR GOLF COURSE DRAINAGE PROJECT

(405) 359-3775

REFERENCES AND SPECIFICATIONS


Explore the references and specifications that verify the AirDrain results in the field.


Click specification format to download:

Golf Drainage Submittal
AirDrain Agronomic Drainage Natural Grass Root Zone Guidelines
ASTM D4716 Flow Rate per Unit Width and Hydraulic Transmissivity
Proper Sequencing and Orientation
Golf Putting Green Drainage Truck and Freight Loading Layout
Golf Putting Green Drainage Cross Section
Golf Putting Green Drainage Detail
Golf Putting Green Drainage Edge Detail
Bunker Renovation Illustrated Manual
Bunker Drainage System
Bunker Drainage Systems Recessed
Golf Tee Box Drainage Cross Section
Golf Tee Box Detail
Golf Tee Box Edge Detail

*These drawings, specifications and the information contained herein are for general presentation purposes only. All final drawings and layouts should be determined by a licensed engineer(s). HIC & Gmax testing are measured in a lab setting and are not site specific.


CAD Details